Lookup tables are computed for use in the lw radiative transfer, and input absorption coefficient data for each spectral band are reduced from 256 g-point intervals to 140.
- Parameters
-
me | print control for parallel process |
rlwinit General Algorithm
- Check cloud flags for consistency.
- Setup default surface emissivity for each band.
- Setup constant factors for flux and heating rate the 1.0e-2 is to convert pressure from mb to \(N/m^2\).
- Compute lookup tables for transmittance, tau transition function, and clear sky tau (for the cloudy sky radiative transfer). tau is computed as a function of the tau transition function, transmittance is calculated as a function of tau, and the tau transition function is calculated using the linear in tau formulation at values of tau above 0.01. tf is approximated as tau/6 for tau < 0.01. all tables are computed at intervals of 0.001. the inverse of the constant used in the pade approximation to the tau transition function is set to b.
Referenced by gfs_rrtmg_setup::radinit().