This module sets up absorption coefficients for band 06: 820-980 cm-1 (low - h2o; high - /) More...
Variables | |
integer, public | msa06 |
msa06=65 | |
integer, public | msf06 |
msf06=10 | |
integer, public | mfr06 |
mfr06=4 | |
integer, public | mmc06 |
mmc06=19 | |
real(kind=kind_phys), dimension(ng06, mfr06), public | forref |
the array forref contains the coefficient of the water vapor foreign-continuum (including the energy term). the first index refers to reference temperature (296,260,224,260) and pressure (970,475,219,3 mbar) levels. the second index runs over the g-channel (1 to NG06=8). | |
real(kind=kind_phys), dimension(ng06, msa06), public | absa |
the array absa(NG06,65) = ka(NG06,5,13) contains absorption coefs at the NG06=8 g-intervals for a range of pressure levels > ~100mb, temperatures, and ratios of water vapor to co2. the first index in the array, jt, which runs from 1 to 5, corresponds to different temperatures. more specifically, jt = 1-5 means that the data are for the corresponding temperature of tref-30, tref-15, tref, tref+15, and tref+30, respectively. the second index, jp, runs from 1 to 13 and refers to the corresponding pressure level in pref (e.g. jp = 1 is for a pressure of 1053.63 mb). the third index, ig, goes from 1 to NG06=8, and tells us which g-interval the absorption coefficients are for. | |
real(kind=kind_phys), dimension(ng06), public | fracrefa |
planck fraction mapping level : p = 473.4280 mb, t = 259.83 k | |
real(kind=kind_phys), dimension(ng06, msf06), public | selfref |
the array selfref contains the coefficient of the water vapor self-continuum (including the energy term). the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 245.6, jt = 2 refers to 252.8, etc. the second index runs over the g-channel (1 to NG06=8). | |
real(kind=kind_phys), dimension(ng06, mmc06), public | ka_mco2 |
the array kao_mxx contains the absorption coefficient for a minor species at the NG06=8 chosen g-values for a reference pressure level below 100~ mb. the first index refers to temperature in 7.2 degree increments. for instance, jt = 1 refers to a temperature of 188.0, jt = 2 refers to 195.2, etc. the second index runs over the g-channel (1 to NG06=8). | |
minor gas mapping level: | |
real(kind=kind_phys), dimension(ng06), public | cfc11adj |
lower - co2, p = 706.2720 mb, t = 294.2 k upper - cfc11, cfc12 original cfc11 is multiplied by 1.385 to account for the 1060-1107 \(cm^{-1}\) band. | |
real(kind=kind_phys), dimension(ng06), public | cfc12 |
This module sets up absorption coefficients for band 06: 820-980 cm-1 (low - h2o; high - /)